ROOF BUILD-UP CONFIGURATOR

Roof insulation – material and U-value calculator.

Enter the roof area and rafters. We calculate insulation between rafters, the over-rafter wood-fibre board, underlay, vapour barrier and OSB – and show the roof U-value right away.
✓ E-shop prices✓ Roof U-value✓ Build-up section
1Roof and rafters
2Over-rafter insulation
More options
3Membranes and inside
Roof underlay (if no over-rafter board, or additionally)
Inner membrane under the rafters (airtight layer)
Loading 3D preview…
Build-up section and U-value
Roof area—
Insulation thickness—
Roof U—
Price per m²—
Your materials
Total incl. VATapproximate, excl. delivery—
How we calculate
  • Insulation between rafters = area × (1 − rafter width / spacing) in rafter depth – we add the STEICO flex pack count.
  • Above-rafter board and OSB: area + 6 % ÷ board area (for tongue-and-groove above-rafter boards the manufacturer's cover area); by default the tongue-and-groove board in the smallest thickness that meets U ≤ 0.15 W/m²K (a square-edged board needs an underlay membrane); membranes: area + 10 % for overlap ÷ roll area; tape for inner membrane joints = area ÷ cover width of the strip (roll width − 10 cm). Steico Multi Membra 5 is a vapour retarder (sd 5 m) – it goes on the inside, not as an underlay.
  • U according to STN EN ISO 6946: the layer with rafters is inhomogeneous – average of the upper and lower limit of resistance, Rsi 0,10, Rse 0,10 (ventilated layer). λ of insulation from the catalogue, timber and OSB 0,13 W/mK (STN EN ISO 10456). Requirements of STN 73 0540-2 for roofs: U ≤ 0,15 (standard), 0,10 (recommended), 0,08 W/m²K (target).
  • Condensation: Glaser method in steady state (inside 20 °C / 50 %, outside −15 °C / 84 %), sd = μ × d from the catalogue or data sheet, membranes as stated by the manufacturer. U value and condensation are indicative – the assessment is done by the designer.
  • According to the manufacturer the STEICO special dry and universal sarking boards are for roof pitches from 16°; STEICO therm dry is not a covering layer – it needs an underlay membrane or sarking board.
  • Fixing of over-rafter insulation and counter battens with long screws into the rafters is determined by a structural engineer (snow, wind) – calculate the screws in the screw calculator.
Total incl. VAT—

FAQ

How do I calculate roof insulation?

Insulation between rafters = roof area × (1 − rafter width ÷ rafter spacing) at rafter depth. Over-rafter boards and OSB are area + 6 % cutting allowance, membranes area + 10 % for overlaps.

What U-value should an insulated roof have?

Under the Slovak standard STN 73 0540-2 the required U-value for roofs is ≤ 0.15 W/m²K, recommended 0.10 W/m²K and target 0.08 W/m²K. The configurator calculates the U-value of your build-up as you go.